SGF20V EATON
Send Print
  1. pin-int

CWDSGF20V

EATON Arrow Hart™ Eaton Wiring Devices SGF20V SGF Duplex Grounding Self-Test GFCI Receptacle, 125 VAC, 20 A, 2 Poles, 3 Wires, Ivory

  • Manufacturers: Eaton
  • Brand Name: EATON
  • BPN: CWDSGF20V
  • MPN: SGF20V
  • UPC:032664750052
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Available at this location: loading -- Locations

EATON arrow Hart™ line of GFCI receptacles ensure electrical shock protection with periodical automatic testing. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. GFCI receptacles are available in a number of grades including hospital, tamper-resistant, non-tamper resistant and weather-resistant, as well as a variety of colors including white, ivory, almond, light almond, black, brown, gray and red.

EATON Arrow Hart™ Eaton Wiring Devices GFCI Receptacle, Duplex Grounding Self-Test, Series: SGF, 125 VAC, 20 A, 60 Hz Frequency, 2 Pole, 3 Wires, NEMA 5-20R NEMA Rating, Specification Grade, -31 to 150.8 deg F, Screw Terminal, Polypropylene/PVC/Thermoplastic, Ivory, 4.2 in H x 1.68 in W x 1.27 in D Dimensions

Amperage Rating      :      20 A
Color      :      Ivory
Dimensions      :      4.2 in H x 1.68 in W x 1.27 in D
Frequency Rating      :      60 Hz
Grade      :      Specification
Material      :      Polypropylene/PVC/Thermoplastic
NEMA Rating      :      NEMA 5-20R
Number of Poles      :      2
Number of Wires      :      3
Series      :      SGF
Temperature Rating      :      -31 to 150.8 deg F
Terminal Type      :      Screw
Type      :      Duplex Grounding Self-Test
Voltage Rating      :      125 VAC
  • Visual indicator lights give quick notification of a tripped or end of life condition
  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Meets and exceeds 10 kA short circuit testing and UL 943 safety standards
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
  • Ground termination with Back-wire clamp provides secure wiring and reduces installation time
  • Tamper-resistant shutters help prevent foreign objects from being inserted
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide superior aesthetics
  • Tapered Back-wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
  • When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
  • Line load miswiring protection, GFCIs will not provide power downstream when wired incorrectly
  • Tri-combo head terminal and mounting screws
  • UL listed, fully compliant with all latest UL 943 class A GFCI requirements
  • Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations
  • pdfCatalog https://assets.unilogcorp.com/2/ITEM/DOC/EATON_TRSGF15B_Brochure.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/2/ITEM/DOC/EATON_TRSGF15B_Instruction_Sheet.pdf
  • pdfOwners/User Manual https://assets.unilogcorp.com/2/ITEM/DOC/EATON_SGF15GY_L_Manual_1.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_06242973fc51ad89b5fc6bd10e4d9c5c5c9df07a7bced49d95809a9b5a26167a.pdf