piwik image

BR4040B200R EATON
Send Print
  1. pin-int

CHDBR4040B200R

EATON BR4040B200R 1-Phase Metallic Main Circuit Breaker Loadcenter, 120/240 VAC, 200 A, 40 Poles, 25 kA Interrupt

  • Manufacturers: Eaton
  • Brand Name: EATON
  • BPN: CHDBR4040B200R
  • MPN: BR4040B200R
  • UPC:786676446303
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Available at this location: loading -- Locations

Specially designed for easy installation, EATON BR 1 in loadcenters house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.

EATON Main Circuit Breaker Loadcenter, 1-Phase Metallic, 120/240 VAC, 200 A, 40 Pole, 25 kA Interrupt, 40 Circuits, BR/BWH Breaker, 3-Wire Wiring Configuration, 40 Spaces, 2/0 AWG to 300 kcmil Wire, Flush Mount, NEMA 3R, NEMA D1R Enclosure Box, 5.19 in L x 14.31 in W x 29.13 in H

Amperage Rating      :      200 A
Breaker Type      :      BR/BWH
Dimensions      :      5.19 in L x 14.31 in W x 29.13 in H
Enclosure Box Size      :      NEMA D1R
Enclosure Type      :      NEMA 3R
Interrupt Rating      :      25 kA
Mounting Type      :      Flush
Number of Circuits      :      40
Number of Poles      :      40
Number of Spaces      :      40
Type      :      1-Phase Metallic
Voltage Rating      :      120/240 VAC
Wire Size      :      2/0 AWG to 300 kcmil
Wiring Configuration      :      3-Wire
  • Flexible neutral design
  • Tangential main knockout
  • Unique sandalwood finish provides an esthetically appealing, scratch-resistant powder coating
  • Factory pre-attached neutral bonding strap
  • Bottom or top feed location
  • Rainproof panels are furnished with hub closure plates, for rainproof hubs
  • For use with type BR 1 in breakers
  • Outdoor rainproof enclosure
  • Copper aluminum wire at 60 to 75 deg C for main breakers
  • Standard tin plated aluminum bus for excellent conductivity and corrosion-resistance
  • No feed through lugs
  • pdfCatalog https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_4699c4093f200f15c8feec0c1d17577c692ad449e7fa8bead4e77755afaf41b2.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_ca16bd8f5db476d34fa75b41ece3caa72dc141327f68d7a38a79a60d860a17b7.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_09fdefb993e9e21e2cf9745abc5f5bce21e2f4bd4c0a8c4035c8920aa90ef5aa.pdf