FX-10RD Edwards Signaling™
Send Print
  1. pin-int

EDWFX10RD

Edwards Signaling™ Kidde FX-10RD 10-Zone Conventional Fire Alarm Control Panel With Dialer, 120/230 VAC Input, 24 VDC Output, 24 VDC, 24 Ah Sealed Lead Acid Battery, Asynchronous Serial Communication, LCD Display, CSFM Approved, FDNY COA 6230

  • Manufacturers: United Technologies
  • Brand Name: Edwards Signaling™
  • BPN: EDWFX10RD
  • MPN: FX-10RD
  • UPC:793016036537
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Available at this location: loading -- Locations

Kidde brand conventional fire alarm systems consist of 5 and 10 zone fire alarm control panels (FACP), an optional integrated upload/download DACT (dialer), intelligent/analog type detector features, serial annunciator modules, and serial remote relay modules. All FACPs and components are listed to the 9th edition of the ANSI/UL 864 standard and CSFM/FDNY approved. These systems incorporate features designed to simplify installation, operation and maintenance, including front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with CleanMe® compatible smoke detectors, these control panels provide intelligent type features such as remote maintenance alert and automatic drift compensation that significantly reduce the chance of a false alarm and simplify maintenance calls. Kidde systems are powerful enough to meet the demands of today's life safety installations while leaving plenty of room to grow in the future. They support class A operation by combining pairs of on-board IDCs or NACs to provide the necessary class A circuits. For example, the FX-10RD comes factory set to support 10 class B IDCs and 4 NACs. But it can be field configured to provide 5 class A IDCs (no class B IDC's) and 2 class A NACs or any other combination of circuits that fall within the circuit-pairing parameters.

Edwards Signaling™ Kidde Fire Alarm Control Panel, 10-Zone Conventional, Series: FX Series, 120/230 VAC Circuit Input, 24 VDC Circuit Output, 24 VDC, 24 Ah Sealed Lead Acid Battery Power Source, Asynchronous Serial Communication, LCD Display, Specifications: 2.2 A at 120 VAC 60 Hz, 1.1 A at 230 VAC 50/60 Hz Input Current, 18 to 12 AWG Terminal, 13 Ohm Maximum Resistance, 0.03 uF Maximum Capacitance, Specifications Met: CSFM Approved, FDNY COA 6230, 30 to 120 deg F, Red, 30 in H x 15 in W x 3-3/4 in D Dimensions

Circuit Input      :      120/230 VAC
Circuit Output      :      24 VDC
Color      :      Red
Communication      :      Asynchronous Serial
Dimensions      :      30 in H x 15 in W x 3-3/4 in D
Display Type      :      LCD
Power Source      :      24 VDC, 24 Ah Sealed Lead Acid Battery
Series      :      FX Series
Specifications Met      :      CSFM Approved, FDNY COA 6230
Specifications      :      2.2 A at 120 VAC 60 Hz, 1.1 A at 230 VAC 50/60 Hz Input Current, 18 to 12 AWG Terminal, 13 Ohm Maximum Resistance, 0.03 uF Maximum Capacitance
Temperature Rating      :      30 to 120 deg F
Type      :      10-Zone Conventional
  • CleanMe® feature provides remote annunciation of a dirty detector
  • Automatic drift compensation with select detectors reduces false alarms and extends dust life
  • Models with fully integrated upload/download DACT enables PC programming
  • Zone or NAC pairs convertible to single class A circuits
  • Combination waterflow and supervisory IDCs
  • NACs programmable by zone and individually selectable for notification appliances, continuous, temporal outputs or coded
  • Front panel programmable simplifies installation and servicing
  • Precision synchronization with compatible notification appliances and optional audible silence over two wires
  • On-board relays for alarm, supervisory and trouble
  • One person walk-test (audible or silent)
  • pdfSpecification Sheet https://assets.unilogcorp.com/2/ITEM/DOC/Edwards_Signaling_FX_5RD_Specification_Sheet.pdf