piwik image

WR139 Blackburn®
Send Print
  1. pin-int

BLAWR139

Blackburn® WR139 Type WR Wide Range Compression H-Tap Connector, H Shape, 4 to 1/0 AWG ACSR, 3 to 2/0 AWG Stranded, 2 to 2/0 AWG Solid Main/Run, 10 to 8 AWG Stranded, 10 to 6 AWG Solid Tap A, 14 to 12 AWG Stranded, 14 to 12 AWG Solid Tap B Tap, Aluminum

  • Manufacturers: Thomas & Betts
  • Brand Name: Blackburn®
  • BPN: BLAWR139
  • MPN: WR139
  • UPC:783786100361
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Available at this location: loading -- Locations

Blackburn® is a complete and reliable line of overhead, grounding, mechanical and compression connectors that respond to a broad range of construction needs.

Blackburn® Compression H-Tap Connector, Type WR Wide Range, H, 4 to 1/0 AWG ACSR, 3 to 2/0 AWG Stranded, 2 to 2/0 AWG Solid Main/Run, 10 to 8 AWG Stranded, 10 to 6 AWG Solid Tap A, 14 to 12 AWG Stranded, 14 to 12 AWG Solid Tap B Tap, ACSR/Aluminum/Copper/Solid/Stranded Conductor, O Die Code, 0.25 to 0.419 in Dia Main Conductor, 0.1 to 0.162 in Dia Tap Conductor A, 0.064 to 0.092 in Dia Tap Conductor B, 3-Conductor, 90 deg C, Aluminum, 1-1/2 in L

Conductor Type      :      ACSR/Aluminum/Copper/Solid/Stranded
Dimensions      :      1-1/2 in L
Main/Run Size      :      4 to 1/0 AWG ACSR, 3 to 2/0 AWG Stranded, 2 to 2/0 AWG Solid
Material      :      Aluminum
Shape      :      H
Specifications      :      O Die Code, 0.25 to 0.419 in Dia Main Conductor, 0.1 to 0.162 in Dia Tap Conductor A, 0.064 to 0.092 in Dia Tap Conductor B, 3-Conductor
Tap Size      :      10 to 8 AWG Stranded, 10 to 6 AWG Solid Tap A, 14 to 12 AWG Stranded, 14 to 12 AWG Solid Tap B
Temperature Rating      :      90 deg C
Type      :      Type WR Wide Range
  • Made of 1350 aluminum alloy for high strength and high conductivity
  • Standard compression tools and dies install all sizes no special tools needed
  • Field proven ribbed design enables excellent connector/conductor contact without distorting the conductor shape
  • Fold-in tabs provide tab interlock as tool closes
  • Prefilled with oxide inhibitor held captive in the rib/connection area
  • Compression/crimp connection
  • 1/0 to 2/0 AWG ACSR, stranded main conductors
  • 2 to 4 AWG ACSR, 1 to 3 AWG stranded, 1 to 2 AWG solid tap conductors
  • pdfSDS https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_2a767eb3984dcb451d364af9fa5287156348973645bdf0af5f2263f86e104f67.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_b37d85507b1f6add3ff339e47088273a16fe14512ad19f01891d0feb2f4b2ac7.pdf