BR816L125FDP EATON
Send Print
  1. pin-int

CHDBR816L125FDP

EATON BR816L125FDP 1-Phase Split Main Lug Loadcenter, 120/240 VAC, 125 A, 16 Poles, 10 kA Interrupt

  • Manufacturers: Eaton
  • Brand Name: EATON
  • BPN: CHDBR816L125FDP
  • MPN: BR816L125FDP
  • UPC:786676001434
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Available at this location: loading -- Locations

Loadcenters are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.

EATON Main Lug Loadcenter, 1-Phase Split, 120/240 VAC, 125 A, 16 Pole, 10 kA Interrupt, 16 Circuits, BR Breaker, 3-Wire Wiring Configuration, 8 Spaces, 14 to 1 AWG Cu/Al Wire, Flush Mounting, NEMA 1 Enclosure, NEMA 7 Enclosure Box, 3.56 in L x 11 in W x 13 in H

Amperage Rating      :      125 A
Breaker Type      :      BR
Dimensions      :      3.56 in L x 11 in W x 13 in H
Enclosure Box Size      :      NEMA 7
Enclosure Type      :      NEMA 1
Interrupt Rating      :      10 kA
Mounting Type      :      Flush
Number of Circuits      :      16
Number of Poles      :      16
Number of Spaces      :      8
Type      :      1-Phase Split
Voltage Rating      :      120/240 VAC
Wire Size      :      14 to 1 AWG Cu/Al
Wiring Configuration      :      3-Wire
  • Twin neutral design located in wireway, away from circuit breakers, means easier wiring and balancing of the load
  • Extra 1-1/2 in knockout for bundling allows maximum wiring gutter space for ease of wiring in compliance with NEC requirements
  • 1-piece roll formed metal backpan with circuit breaker alignment notches ensures accurately aligned breaker and bus tabs
  • Standard 14-3/8 in W enclosures fit snugly between wall studs
  • Tangential main knockout eliminates the need for conduit offsets which permits faster, easier installation
  • BR load centers feature Robertson slotted square combo screw heads, which means only one screwdriver is need for installation
  • Indoor enclosure
  • Copper aluminum wire at 60 to 75 deg C for main lugs
  • Standard tin plated aluminum bus for excellent conductivity and corrosion-resistance
  • Dual grounds, current design
  • pdfCatalog https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_4699c4093f200f15c8feec0c1d17577c692ad449e7fa8bead4e77755afaf41b2.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_ca16bd8f5db476d34fa75b41ece3caa72dc141327f68d7a38a79a60d860a17b7.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/2/ITEM/DOC/IDW_DOCUMENT_c8a8e644c9a9f8185a330497dabb547d96837973adc609a3097f75b4ead05878.pdf