EATON Arrow Hart® TRSGFA15V TRSGFA Duplex Grounding Self-Test Tamper-Resistant GFCI Receptacle With Audible Alarm, 125 VAC, 15 A, 2 Poles, 3 Wires, Ivory

  • Manufacturers: Eaton
  • Brand Name: EATON
  • BPN: CWDTRSGFA15V
  • MPN: TRSGFA15V
  • UPC:032664748042
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Available at this location: loading -- Locations

GFCI receptacles are designed with the safety of the user in mind. In commercial and industrial areas like public bathrooms, breakrooms and food service areas, the NEC requires GFCI receptacles. Arrow Hart® GFCI receptacles are UL listed and fully compliant with all of the latest UL 943 class A GFCI and UL 498 requirements. The GFCI's conduct an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available. Additionally, GFCIs incorporate a safety lock out function to protect against mis-wired line load connections and GFCI circuitry damage.

EATON Arrow Hart® GFCI Receptacle, Duplex Grounding Self-Test Tamper-Resistant, Series: TRSGFA, 125 VAC, 15 A, 60 Hz Frequency, 2 Pole, 3 Wires, NEMA 5-15R NEMA Rating, Specification Grade, -31 to 150.8 deg F, Screw Terminal, PVC/Thermoplastic/Nylon 6/6, Ivory, 4.19 in H x 1.2 in D Dimensions

Amperage Rating      :      15 A
Color      :      Ivory
Dimensions      :      4.19 in H x 1.2 in D
Frequency Rating      :      60 Hz
Grade      :      Specification
Material      :      PVC/Thermoplastic/Nylon 6/6
NEMA Rating      :      NEMA 5-15R
Number of Poles      :      2
Number of Wires      :      3
Series      :      TRSGFA
Temperature Rating      :      -31 to 150.8 deg F
Terminal Type      :      Screw
Type      :      Duplex Grounding Self-Test Tamper-Resistant
Voltage Rating      :      125 VAC
  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or "end of life" condition
  • Audible alarm notifies user of tripped GFCI, alarm can be turned off if required
  • Meets and exceeds 10 kA short circuit testing and UL 943 safety standards
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
  • Ground termination with back wire clamp provides secure wiring and reduces installation time
  • Tamper resistant shutters help prevent foreign objects from being inserted
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide superior aesthetics
  • Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
  • When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
  • Line load miswiring protection, GFCIs will not provide power downstream when wired incorrectly
  • Tri-combo head terminal and mounting screws
  • Longer, wider "bridged" strap provides 40% more contact area with wallboard, virtually eliminating floating installations
  • pdfInstruction/Installation Manual https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/EATON_TRSGF15B_Instruction_Sheet.pdf
  • pdfSpecification Sheet https://externalassets.unilogcorp.com/ASSETS/DOCUMENTS/ITEMS/EN/IDW_DOCUMENT_023c5d08dfcf7f21eb526f0d7323ba1a750f37364e3b64db363b9076a92c0798.pdf